Offer
Parameters

Parameters

Effectiveness is our goal!

TDC is vigorously developing company which sets itself gradually higher demands in all fields of its business. We know that signage is the most important for safety thus we are constantly broadening our ware and uprate lightning parameters of our photoluminescent signs. Currently, all of our glowing signs exceed the requirements of DIN 67510 norm ten times. In order to facilitate you getting around types and power of our ware, we introduced following designations:


SL/2

Standard glowing technology intended for well and medium lighted rooms (offices, shops, schools etc.).


SL/5*

Upgraded glowing technology intended for:

  • poorly or non-continuously lighted rooms (hospitals, stores, hotel corridors, underground passages, garages etc.);
  • low location-lightning (LLL) Safety Way Guidance System (SWGS);
  • sea ships’ signage.

SL/8*

Advanced glowing technology near very high lightning parameters fulfils requirements regarding surface flammability and toxicity. This technology is intended for:

  • places lighted very poorly, when the bundle of activating light is very small;
  • tunnel signage, underground passages, garages;
  • sea ships’ signage.

SL/8 signs are most commonly chosen by the military and police.


signs sl/2
material luminance after the passage of time (mcd/m2) the loss of light
(min)
2 min 5 min 10 min 30 min 60 min 120 min
Film (F) Board (P) 513,71 209,71 106,31 33,51 15,31 6,73 1710
Polycarbonate (W) 525,71 229,71 116,31 35,81 16,11 7,03 1740
System TD® (T) 342,81 149,01 76,38 23,81 10,79 4,73 1270
signs sl/5
material luminance after the passage of time (mcd/m2) the loss of light
(min)
2 min 5 min 10 min 30 min 60 min 120 min
Film (F) Board (P) 682,70 279,70 140,90 43,70 19,70 8,60 2010
Polycarbonate (W) 650,71 270,71 134,91 41,61 18,71 8,07 1880
System TD® (T) 478,71 194,71 97,51 29,91 13,39 5,78 1420
Aluminium (ALU) 951,23 394,23 195,23 58,23 26,03 11,08 2090
signs sl/8
material luminance after the passage of time (mcd/m2) the loss of light
(min)
2 min 5 min 10 min 30 min 60 min 120 min
Aluminium (ALU) 1486,2 638,23 319,23 96,23 42,03 17,53 3200
the polish norm: PN - 92/N - 01256/01
  luminance after the passage of time (mcd/m2) the loss of light
(min)
2 min 5 min 10 min 30 min 60 min 120 min
- - - - - 0,32 120
the norm DIN 67510
  luminance after the passage of time (mcd/m2) the loss of light
(min)
2 min 5 min 10 min 30 min 60 min 120 min
- - 20 - 2,80 - 340
the norm ISO / FDIS 17398
  luminance after the passage of time (mcd/m2) class
2 min 5 min 10 min 30 min 60 min 120 min
108 - 23 7 3 - A
210 - 50 15 7 - B
690 - 140 45 20 - C
1100 - 260 85 35 - D
Download detailed technical cards of our products

Subscribe to TDC newsletter

BE UP-TO-DATE WITH:
Please, enter your e-mail address

The Controller of Personal Data is TDC-TOP DESIGN CHUDZYŃSCY SPÓŁKA JAWNA located in Chwaszczyno ul. Oliwska 166, 80-209 (hereinafter referred to as: Company). The Controller appointed Data Protection Officer who can be reached at via e-mail, or via mail: ul. Oliwska 166, 80-209 Chwaszczyno. Personal Data will be processed for purposes such as sending commercial information by the Company regarding Company’s offers, in the electronic or telephonic form (depending on preferences), or sharing the Personal Data to the delivery company including: name and surname, address and telephone number to fill in the order, based on the consent, in Article 6, point 1 of Regulation, (EU) 2016/679 of the European parliament and of the council of 27 April 2016 on the protection of natural persons with regard to the processing of personal data and on the free movement of such data, and repealing Directive 95/46/EC (hereinafter referred to as GDPR). Personal Data can be shared with the employees or co-workers of the Company, as well as with the entities helping the Company by performing the commissioned services in line with the processing agreements. Each person has the right to access the content of their data, and rectify, delete, limit, move the processed data, has the right to raise objections regarding the data processed, and the right to revoke the consent at any time without the impact on accordance with the right of processing, as well has the right to file a complaint to the European Commission Data Protection Officer if he recognizes that processing violates GDPR regulations. Giving the personal data is voluntary.